Method of using microwave level switch.si tex metadata class b ais transceiver

Time:2024-04-11 Views:1

  

high power rf circulator

  First of all, the installation location should be suitable. The microwave level switch is installed above the material to be measured and kept at a certain distance from the material to be measured. If the material has a fixed height, the switch should be installed near this height. If the height of the material changes greatly, this situation needs to be taken into account in the installation position. The installed microwave level switch should not interfere too much with the sensor body.

  Second, the cables and power supply should be connected correctly. For outdoor microwave level switches, protective covers or waterproof leather covers should be installed on the cable part to avoid being affected by the external environment. When connecting the cable, the power should be turned off first, and then the cable should be inserted into the connection port of the sensor to ensure good contact.

  Then, the meter should be configured correctly. In order to use the microwave level switch to measure the position of the material, it is necessary to configure the instrument reasonably. Set according to the required measurement range, allowable error, dielectric constant of the material to be measured and other factors. It is necessary to pay attention to the parameter selection during the setting, and its setting should also be selected according to the actual situation of the site, such as the dielectric constant, temperature, humidity, etc. After the setting is correct, it is necessary to monitor continuously during the measurement process to determine whether the measurement is accurate. If there is any error, it should be adjusted in time.

  Then, routine maintenance. The service life of the microwave level switch has a great relationship with its quality, installation position and surrounding environment. Therefore, it is necessary to pay attention to maintenance during use. For example, the main body of the microwave sensor is cleaned, impurities are removed, and regular maintenance is carried out. In addition, keep the power supply dry, the wires in good contact, and replace the battery and internal lines in time. Minimize possible damage caused by adjusting switches and other operations.