Trunk amplifiers are generally used to cooperate with micro-cell base stations or repeaters to solve indoor signal blind spots. They adopt a dual-port full-duplex design, built-in power supply, easy installation, high reliability, and are compatible with digital and analog systems.
It has the advantages of light weight, small size, simple and convenient installation.
The working frequency band can be customized according to customer needs.
Frequency Range | Uplink: 330~520MHz | Downlink:330~520MHz |
Working bandwidth | <5MHz | <5MHz |
Duplex interval | >5MHz | >5MHz |
Gain | 45±2dB / 50±2dB | 45±2dB / 50±2dB |
Gain adjustment range | 30dB in 1dB Step | 30dB in 1dB Step |
In-band fluctuations | ≤±1.5dB | ≤±1.5dB |
Output Power | 3dBm | 37dBm(5W)/ 43dBm(20W) |
In-band intermodulation attenuation | ≤-45dBc | ≤-45dBc |
Stray | ≤-36dBm@9KHZ~1GHz; ≤-30dBm@1GHz~12.75GHz | |
ALC starting control depth | 20dB | 20dB |
VSWR | ≤1.5:1 | ≤1.5:1 |
Group delay | ≤2.5us | ≤2.5us |
Noise Figure @Maximum Gain | ≤5dB | --- |
Impedence | 50Ω | |
Local monitoring | RS232 | |
Remote monitoring (optional) | GSM SMS modem or Ethernet | |
Powered by | 110VAC or 220V AC(±15%),50~60Hz | |
Power consumption | ≤90watts | |
Mean time between failures (MTBF) | 50,000 hours | |
IP protection level | IP65 | |
Heat dissipation | Natural heat dissipation | |
Working temperature range | -20~+55°C | |
Working humidity range | 0~95%(non-condensing) | |
Monitoring protocol requirements | Meet China Mobile network management agreement requirements | |
Mechanical dimensions (L*W*H) | 440mm*300mm*170mm / 530mm*300mm*170mm |